Rev. Col. Bras. Cir ; 48: e20202587, 2021. graf
Article in English | LILACS | ID: biblio-1155357

ABSTRACT

ABSTRACT Objectives: the aim of this study was to compare the outcomes of a new silicone vascular prostheses with PTFE vascular prostheses, on a rabbit experimental model. Methods: forty rabbits underwent infra-renal aorta replacement with 4 mm diameter prostheses, twenty animals with PDMS and twenty animals with PTFE (control group). Retrograde aortic angiography was performed to assess patency. Histological graft samples were examined by electron microscopy to evaluate prostheses endothelialization. Results: patency rates were 100% for both grafts after 30 days; after 60 days, patency rate for PDMS was 92.3% (±7.4), and 73,8% (±13.1) at 90 days. PTFE grafts had patency rates of 87.5% (±11.7) at 60 and 90 days. No statistically significant difference was found in between groups for patency rates (p=0.62). Postoperative complications (death, paraplegia) rates (p=0.526) and aortic clamping times (p=0.299) were comparable in both groups. No statistically significant difference for stenosis was found on angiographical analysis between groups (p=0.650). Electron microscopy revealed limited anastomotic endothelial ingrowth in both prostheses. Conclusion: in this experimental model, PDMS and PTFE vascular prostheses had comparable outcomes and PDMS prosthesis could be used as a vascular graft.


RESUMO Objetivo: analisar novo tubo de silicone como material para prótese vascular e compará-lo a prótese de PTFE, em modelo experimental com coelhos. Métodos: quarenta coelhos foram submetidos a interposição, na aorta infrarrenal, de próteses de 4mm de diâmetro, sendo 20 animais com PDMS e 20 com PTFE (grupo controle). Foi realizada arteriografia retrógrada da aorta para avaliar a patência das próteses. Para avaliar a endotelização das próteses foi realizada microscopia eletrônica de maneira amostral pareada. Resultados: a patência em 30 dias foi de 100% para as duas próteses. Aos 60 dias, a taxa de patência do PDMS foi de 92,3% (± 7,4), e de 73,8% (±13,1) em 90 dias; as próteses de PTFE tiveram taxas de patência de 87,5% (± 11,7) aos 60 e 90 dias. Não foi observada diferença significativa entre as taxas de patência dos grupos (p=0,62). Não foi observada diferença entre os grupos quanto à evolução com complicações pós-operatórias (p=0,526) e quanto ao tempo de clampeamento da aorta (p=0,299). Não houve diferença significativa entre os grupos quanto ao grau de estenose das próteses (p=0,650) à avaliação angiográfica. A microscopia eletrônica mostrou crescimento endotelial limitado às regiões próximas às anastomoses nos dois tipos de próteses. Conclusões: o PDMS mostrou-se passível de utilização como prótese vascular, com resultados comparáveis aos do PTFE no modelo utilizado.


Subject(s)
Animals , Aorta/surgery , Polytetrafluoroethylene/therapeutic use , Silicones/therapeutic use , Blood Vessel Prosthesis , Polyesters , Rabbits
2.
Arq. bras. oftalmol ; 83(1): 39-42, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088957

ABSTRACT

ABSTRACT Purpose: To review the outcomes of frontalis suspension surgeries with the use of polytetrafluoroethylene in patients with blepharoptosis. Methods: A retrospective observational study analyzed the outcomes of frontalis suspension surgeries performed in a single institution from 2003 to 2018. All procedures were performed with closed incision and single pentagon techniques. Outcomes were classified as satisfactory or unsatisfactory, with satisfactory defined as a margin reflex distance of >3 mm and <1 mm between eyelids and unsatisfactory as hypocorrection, surgical complications, and asymmetry. Results: We included a total of 76 eyelids from 52 patients in our study. Within a mean postoperative follow-up of 16.8 ± 18.5 months (range, 3-95), 59 (77.6%) eyelids had a satisfactory outcome, and 17 (22.4%) were unsatisfactory (8 cases of asymmetry, 3 granulomas, 3 suture extrusions, 2 abscesses, and 1 case of cellulitis). Nine eyelids from the unsatisfactory group required reoperation. Among the patients with a follow-up of ³12 months (38 surgeries), lasting results were observed in most eyelids, except for 2 late-onset suture extrusions. Conclusion: The use of polytetrafluoroethylene in frontalis suspension surgery was shown to be predictable, safe, and lasting. Our findings support previous studies that have shown adequate functional results and low complication rates.


RESUMO Objetivo: Revisar os resultados de cirurgias de sus pensão ao músculo frontal com o uso de fio de politetrafluoretileno em pacientes com blefaroptose. Métodos: Em um estudo observacional retrospectivo, foram analisados os resultados das cirurgias de músculo frontal de uma instituição, realizadas entre 2003 e 2018. Todos os procedimentos foram realizados com incisão fechada e técnica de pentágono. Os desfechos foram classificados como satisfatórios ou insatisfatórios com definição satisfatória definida como distância margem-reflexo >3mm e <1mm entre as pálpebras e insatisfatória como hipocorreção, complicações cirúrgicas e assimetria. Resultados: Incluímos um total de 76 pálpebras de 52 pacientes em nosso estudo. Com um tempo médio de seguimento pós-operatório de 16,8 ± 18,5 meses (intervalo 3-95), 59 (77,6%) pálpebras apresentaram desfecho satisfatório e 17 (22,4%) insatisfatórios (8 casos de assimetria, 3 granulomas, 3 extrusões de sutura, 2 abscessos e 1 caso de celulite). Nove pálpebras do grupo insatisfatório necessitaram de reoperação. Entre os pacientes com seguimento ³12 meses (38 cirurgias), resultados duradouros foram observados na maioria dos casos, exceto por 2 extrusões de sutura de surgimento tardio. Conclusão: O uso de politetrafluoretileno na cirurgia de músculo frontal mostrou ser previsível, seguro e duradouro, Nossos achados corroboram com estudos prévios que mostraram resultados funcionais adequados e baixos índices de complicação.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Young Adult , Polytetrafluoroethylene/therapeutic use , Blepharoptosis/surgery , Blepharoplasty/methods , Eyelids/surgery , Oculomotor Muscles/surgery , Postoperative Complications , Reoperation , Retrospective Studies , Suture Techniques , Treatment Outcome
3.
Braz. dent. sci ; 21(4): 445-450, 2018. tab, ilus
Article in English | LILACS, BBO | ID: biblio-966307

ABSTRACT

Objective: Evaluate the bond strength of resin cements to new materials for application in intraradicular posts. Material and Methods: Five materials were evaluated: fiberglass, PET, polyethylene, polyacetal and PTFE. Two commercial resin cements (Rely X U200 and Rely X Arc) were applied on the test specimens of the materials (9x3mm) and the bonding was evaluated through the shear bond strength test, where the chisel operated with a load of 1kN and a velocity of 0.5mm/min at the cement/material interface. The data were analyzed by the Shapiro-Wilk test, followed by the two-way analysis of variance, performed with the Bonferroni post-test (α=0.05). Results: The glass fiber was statistically different from all evaluated materials (p0.05). Comparing the two cements, a statistical difference was found between Rely X U200 and Arc only for the glass fiber (p=0). Conclusion: PET, polyethylene, polyacetal and PTFE exhibited reduced bond strength compared to the glass fiber (AU)


Objetivo: Avaliar a resistência de união de cimentos resinosos a novos materiais para aplicação em pinos intrarradiculares. Material e método: Foram avaliados cinco materiais: fibra de vidro, PET, polietileno, poliacetal e PTFE. Dois cimentos resinosos comerciais (Rely X U200 e Rely X Arc) foram aplicados sobre os corpos de prova dos materias (9x3mm) e a resistência de união foi avaliada através do teste de cisalhamento, onde o cinzel atuou com carga de 1kN e velocidade de 0,5mm/min na interface cimento/material. Verificada a normalidade dos dados através do teste Shapiro-Wilk, foi realizada a análise de variância de dois fatores com pós-teste de Bonferroni (α=0,05). Resultados: a fibra de vidro foi diferente estatisticamtente de todos os materiais avaliados (p0,05). Comparando-se os dois cimentos, foi encontrada diferença estatística entre o Rely X U200 e Arc apenas para a fibra de vidro (p=0). Conclusão: PET, polietileno, poliacetal e PTFE apresentaram resistência de união reduzida comparando-se à fibra de vidro. (AU)


Subject(s)
Polytetrafluoroethylene , Polyethylene Terephthalates , Resin Cements
4.
J. vasc. bras ; 14(2): 133-138, Apr.-June 2015. tab, ilus
Article in English | LILACS | ID: lil-756461

ABSTRACT

BACKGROUND: Many chronic renal patients lack autologous veins in the upper limbs suitable for construction of arteriovenous fistulas for hemodialysis. Alternative fistula options for these patients should be evaluated and compared.OBJECTIVE: To compare different types of grafts used for brachioaxillary access in hemodialysis patients in terms of their patency and complication rates.METHOD: Forty-nine patients free from arterial system abnormalities and with no venous options for creation of arteriovenous fistulae in the arm and/or forearm underwent brachioaxillary bypass with implantation of autologous saphenous vein, polytetrafluoroethylene (PTFE), or PROPATEN(r) grafts. Patients were assessed by Doppler ultrasonography at 3, 6, and 12 months after surgery. RESULTS: The four first saphenous vein grafts had failed by 3 or 6 months after surgery. The autologous saphenous vein group was discontinued at the beginning of the study because of extreme difficulty in achieving puncture and hematoma formation. Failure rates of PTFE and PROPATEN(r) grafts did not differ after 3 (p = 0.559), 6 (p = 0.920), or 12 months (p = 0.514). A log-rank test applied to cumulative survival of grafts at 1 year (0.69 for PTFE, 0.79 for PROPATEN(r)) detected no significant differences (p = 0.938). There were no differences in complications resulting in graft failure between the two types of prosthetic graft.CONCLUSION: Autologous saphenous vein grafts do not appear to be a good option for brachioaxillary hemodialysis access because of difficulties with achieving puncture. Brachioaxillary fistulae constructed using PTFE or PROPATEN(r) grafts exhibited similar patency and complication rates. Further studies with large samples size are warranted to confirm our findings.


CONTEXTO: Há inúmeros pacientes renais crônicos sem veias autólogas nos membros superiores para confecção de fístulas arteriovenosas para realização de hemodiálise. As opções de fístula nestes pacientes devem ser avaliadas e comparadas.OBJETIVO: Comparar diferentes enxertos para acesso braquioaxilar em pacientes hemodialíticos, em relação a permeabilidade e taxas de complicação. MÉTODO: Um grupo de 49 pacientes, sem alterações no sistema arterial e sem opções venosas para criação de fístula arteriovenosa no braço e/ou antebraço, foi submetido a procedimentos cirúrgicos para implante de diferentes enxertos: veia safena autóloga, enxertos de PTFE e PROPATEN(r).RESULTADOS: Os quatro primeiros implantes de veia safena falharam no terceiro e no sexto mês após a cirurgia. Interrompeu-se o uso de veia safena autóloga no início do estudo pela extrema dificuldade de punção e pela formação de hematoma. Não houve diferenças nas taxas de falha dos enxertos de PTFE e PROPATEN(r) após três (p = 0,559), seis (p = 0,920) e 12 meses (p = 0,514) de seguimento. O teste de Logrank aplicado à sobrevida cumulativa dos enxertos por um ano (0,68 para PTFE; 0,79 para PROPATEN(r)) não relevou diferenças (p = 0,938). Não foram encontradas diferenças entre os enxertos prostéticos em relação ao tipo de complicação que determinou as falhas.CONCLUSÃO: O enxerto de veia safena autóloga parece não ser é uma boa opção para acesso braquioaxilar em hemodialíticos, já que implica em dificuldade na punção. Os enxertos de PTFE e PROPATEN(r) em fistula braquioaxilar resultaram em permeabilidade e taxas de complicações similares. Estudos com amostras maiores são necessários para confirmar nossos achados.


Subject(s)
Humans , Male , Female , Brachial Artery/surgery , Renal Dialysis/methods , Arteriovenous Fistula/surgery , Arteriovenous Fistula/complications , Treatment Outcome , Saphenous Vein/surgery , Heparin/administration & dosage , Polytetrafluoroethylene , Survival Analysis , Upper Extremity , Vascular Access Devices
5.
Braz. dent. sci ; 17(4): 53-64, 2014. ilus, graf
Article in English | LILACS | ID: lil-742516

ABSTRACT

Objective: The aim of this study was to evaluate the effectiveness of platelet rich plasma with and without autogenous bone graft in the bone repair of surgical defects in rabbit tibias. Material and Methods: In this research, 25 adult male rabbits were used. Two defects have been performed in each tibia, divided into four groups: control (C = defect naturally left to heal by clot formation), autogenous (A = bone defect + autogenous graft), PRP (PRP = bone defect + PRP) and autogenous + PRP (PRPA = bone defect + autogenous graft + PRP). All the defects were covered with a dPTFE membrane. Five other animals were sacrificed at 15, 30, and 60-day postoperatively. The pieces containing the defects were processed for histological and histomorphometric analysis. Other five animals were sacrificed after 30 and 60 days and submitted to biomechanical analysis, and all the specimens were sent to the radiographic evaluation of optical density. Results: The biomechanical, radiographic, and histomorphometric results showed larger resistance, optical density, and improving bone formation in the groups A and PRPA when compared with the groups C and PRP. Conclusion: This study showed there was not an improvement in the radiographic, mechanical, and bone formation parameters when PRP was used individually or associated to the autogenous bone graft...


Objetivo: O propósito deste trabalho foi avaliar o efeito do plasma rico em plaquetas associados ou não ao enxerto ósseo autógeno no processo de reparação óssea em defeitos cirúrgicos confeccionados na tíbia de coelhos. Material e Métodos: Nesta pesquisa foram utilizados 25 coelhos adultos, nos quais foram realizados 2 defeitos em cada tíbia, divididos nos seguintes grupos de acordo com o tratamento: controle (C - defeito preenchido somente por coágulo sangüíneo), autógeno (A - defeito + enxerto), PRP (PRP = defeito + PRP) e autógeno + PRP (PRPA - defeito + enxerto + PRP). Todos os defeitos foram recobertos com uma barreira de PTFE e decorridos 15, 30 e 60 dias, 5 animais foram sacrificados por período, sendo as peças contendo os defeitos processadas para análises histológica e histomorfométrica. Outros 5 animais foram sacrificados aos 30 e 60 dias e submetidos à análise das propriedades biomecânicas e todos os espécimes foram submetidos ao exame radiográfico para análise da densidade óptica. Resutados: Os resultados biomecânicos, radiográficos e histomorfométricos mostraram maior resistência, densidade óptica e maior formação óssea nos grupos A e PRPA quando comparados com os grupos C e PRP. Conclusão: Os resultados obtidos possibilitaram concluir que não houve uma melhora nos parâmetros radiográficos, mecânicos e na neoformação óssea quando o PRP foi usado isoladamente ou associado ao enxerto ósseo autógeno...


Subject(s)
Animals , Rabbits , Bone Regeneration , Bone Transplantation , Membranes , Platelet-Rich Plasma , Polytetrafluoroethylene
6.
São Paulo; s.n; 2014. [72] p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-750126

ABSTRACT

Introdução: Apesar de bons resultados descritos na literatura, o substituto ideal para a utilização como remendo no fechamento arterial ainda não existe. Por este motivo, ainda há espaço para a busca por remendo que seja biocompatível, e que apresente facilidade de manuseio e resultados satisfatórios. Avaliamos remendos arteriais de silicone (polidimetilsiloxano com reforço em poliéster - PDMSr) em comparação com remendos arteriais de PTFEe. Objetivo: O objetivo deste trabalho é comparar, em modelo experimental, em coelhos, os resultados de remendos arteriais feitos em PDMSr com remendos de PTFEe. Materiais e Método: A amostra foi definida em 10 animais que completassem todas as etapas da pesquisa em cada grupo. Os animais foram submetidos à laparotomia mediana e abertura longitudinal da aorta de aproximadamente 8mm, realizando-se o seu fechamento com remendo do grupo selecionado, seguido do fechamento por planos. Os animais foram mantidos em biotério até o 60º PO, quando, então, realizou-se arteriografia de controle, e análise macro e microscópica de peça. Resultados: Para se atingir a amostra desejada, foram necessários 12 procedimentos no grupo PDMSr e 16 no grupo PTFEe. Ocorreram 2 óbitos no grupo PDMSr e 6 no grupo PTFEe. Apesar do número maior de óbitos no grupo PTFEe não houve diferença estatística na sobrevida entre os grupos. Um animal do grupo PDMSr apresentou monoparesia em pata posterior direita e um animal do grupo PTFEe apresentou hérnia incisional. Não houve diferença estatística nas complicações entre os grupos. O tempo operatório foi estatisticamente maior no grupo PTFEe quando comparamos todos os animais, fato que não se repetiu quando excluímos os animais que faleceram...


Introduction: Although good results are reported for various materials for use as patches for arterial closure, as yet none of these is ideal. Therefore, research is continuing into development of a patch that is biocompatible and provides ease of handling, while having satisfactory outcomes. A new silicone arterial patch (polydimethylsiloxane reinforced with polyester fabric, PDMSr) was compared with patches made of expanded polytetrafluoroethylene (ePTFE). Objective: To compare the outcomes between arterial patches made of PDMSr with those made of ePTFE, in an experimental rabbit model. Materials and Method: Rabbits were placed in two groups, and received either PDMSr or ePTFE arterial patches (PDMSr group and ePTFE group, respectively). The animals underwent laparotomy and longitudinal opening of the aorta, which was then closed with the selected patch, followed by suture of all layers. The animals were kept in their cages until the 60th postoperative day, when arteriography, removal of the aorta, and macroscopic and optic and scanning electron microscopic analyzes of the aorta were performed. Ten rabbits from each group that had completed all stages of the research were included in analyses. Results: Twelve procedures were performed in the PDMSr group and 16 in the ePTFE group. There were 2 deaths in the PDMSr group and 6 in the ePTFE group. Despite the higher number of deaths in the ePTFE group, there was no statistical difference in survival rate between the groups. One animal in the PDMSr group developed monoparesis in its right hind paw and 1 animal in the ePTFE group had an incisional hernia. There was no statistical difference in complications between the groups. The operative time was significantly longer in the ePTFE group when all animals were included in analysis, but not when animals that died were excluded...


Subject(s)
Animals , Female , Rabbits , Aorta, Abdominal/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation , Dimethylpolysiloxanes , Endothelium, Vascular , Polyesters , Polytetrafluoroethylene , Silicones , Vascular Grafting , Vascular Patency , Implants, Experimental , Rabbits
7.
Araraquara; s.n; 2013. 119 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867791

ABSTRACT

O objetivo deste estudo foi: A) avaliar a influência de diferentes materiais obturadores do canal de acesso ao parafuso sobre a resistência à fratura da resina de selamento, B) avaliar a influência do selamento do orifício de acesso ao parafuso (OAP) sobre a resistência à fratura da porcelana de cobertura. Para a confecção dos corpos-de-prova das duas partes do estudo foram usados componentes protéticos do tipo UCLA anti-rotacional (Biomet 3i) para implantes de hexágono externo com plataforma de 5,0 mm de diâmetro. Na primeira parte do estudo, foram testadas as resinas compostas fotopolimerizáveis Z100 e P60 (3M ­ ESPE) para selar o OAP, e como materiais de obturação do canal foram utilizados algodão hidrófilo, fita de politetrafluoretileno (fita veda rosca) e guta-percha. Os corpos-de-prova foram fundidos em liga de NiCr, e uma camada de 2,0 mm de espessura de porcelana feldspática foi aplicada sobre a face onde estava localizado o orifício de acesso ao parafuso. A porcelana do OAP foi jateada com óxido de alumínio, condicionada com ácido fluorídrico 10 %, e recebeu aplicação de silano e agente adesivo. Após a condensação do material obturador, o orifício foi selado com a resina composta, de acordo com o grupo experimental proposto e efetuado o teste de resistência à fratura por meio de uma força axial compressiva aplicada no centro da superfície do selamento até a fratura. Os valores foram analisados estatisticamente por meio da ANOVA um fator e teste de Tukey (p≤0,05). O melhor selamento foi observado com a resina P-60 associada ao algodão. Na segunda parte do estudo, foram confeccionadas 30 coroas metalocerâmicas implanto-suportadas, correspondentes a um molar inferior, e divididas igualmente nos seguintes grupos: 1) coroas parafusadas com o orifício de acesso selado através do protocolo de melhor resultado na primeira parte do estudo; 2) coroas parafusadas com o orifício não selado; 3) coroas cimentadas implantossuportadas. Todas as coroas foram padronizadas e submetidas ao ensaio mecânico com uma força axial compressiva concomitantemente sobre as vertentes triturantes das cúspides vestibulares e linguais até a fratura da coroa. Os dados foram analisados pela ANOVA dois fatores e teste de Dunnett para comparações múltiplas, com nível de significância de 5%. Os resultados mostraram não haver diferenças significantes entre os grupos 1 e 2, sendo que os maiores valores médios de resistência à fratura foram obtidos pelo grupo 3. As conclusões do estudo foram as seguintes: o material obturador influenciou na resistência à fratura da resina composta utilizada para selar o OAP; o selamento do OAP não aumentou a resistência à fratura da porcelana de cobertura das coroas parafusadas


The purposes of this study were: A) to assess the influence of filling materials on the fracture resistance of resin composites used to seal the SAH; B) to assess the influence of sealing of the (SAH) on the fracture resistance of metal-ceramic (MC) screw-retained implant-supported restorations. An UCLA plastic abutment to external hexagon implant with a diameter of 5.0 mm was used to perform the experimental samples of the two research parts. In the first part, the resin composite, Z-100 and P-60, were used to seal the SAH, and the filling materials used were cotton pellets, polytetrafluorethylene tape and gutta-percha. The experimental samples were cast in NI-Cr metal alloy a ceramic layer with 2.0 mm of diameter was applied on the surface where is placed the SAH. The ceramic surface of the SAH was airabraded with aluminum oxide, etched with 10% hydrofluoric acid, and a silane coupling agent and a bonding agent were applied. After condensation of the filling materials, the SAH was sealed with resin composite and an axial compression load was applied at the central of the sealing restoration until the fracture. Data were analyzed using two-way ANOVA and Tukey HSD test (p < 0.05). The best sealing was with P60 associated with absorbent cotton. In the second part, were performed 30 implant-supported restorations divided equally into 3 groups: 1) screw-retained restorations with restored screw access hole; 2) screw-retained restorations with unrestored screw access hole; 3) cement-retained restorations. All restorations were standardized and underwent to an axial compression load applied simultaneously on the buccal and lingual incline cusps until fracture. Data were analyzed using one-way ANOVA and Dunnett test for multiple comparisons, and the statistical significance was set at p < 0,05. No significant difference between screw-retained restorations was found. The highest mean fracture resistance values were observed with group 3. The following conclusions were reached: the filling material influenced on fracture resistance of resin composite used to seal the SAH; the sealing of the SAH did not increase the porcelain fracture resistance of the screw-retained crowns


Subject(s)
Analysis of Variance , Ceramics , Polytetrafluoroethylene , Dental Prosthesis , Dental Prosthesis, Implant-Supported , Dental Restoration Repair , Composite Resins , Materials Science
8.
J. coloproctol. (Rio J., Impr.) ; 32(4): 416-421, Oct.-Dec. 2012. ilus
Article in English | LILACS | ID: lil-678275

ABSTRACT

Sacrococcygeal hernia consists of the protrusion of abdominal and pelvic structures through the sacrococcygeal region, an uncommom complication of coccygectomy and sacral coccygectomy. Its surgical treatment is based on perineal hernia repair, by means of abdominal, perineal or abdominoperineal access. Perineal (local or sacrococcygeal) access avoids the laparotomy morbidity and is indicated to patients that are not exposed to radiation or those who had not undergone oncological surgery, allowing local tissue to reconstruct, as in myocutaneous advancement flaps, associated or not to prosthetic mesh, because of the low complication rates and favourable outcomes. The aim of this article is to report the case of a female patient who had undergone sacral coccygectomy due to refractory coccygodynia and developed a symptomatic sacrococcygeal hernia. She underwent polytetrafluoroethylene mesh herniorrhaphy followed by soft tissue closure and gluteal myocutaneous V-Y advancement flap. The authors emphasize technical details and the difficulty of the procedure itself. After three years of follow-up, no recurrence was found. (AU)


As hérnias sacrococcígeas são protrusões de estruturas pélvicas e abdominais pela topografia do sacro e cóccix, sendo complicação incomum após coccigectomias ou sacrococcigectomias. O tratamento é cirúrgico e baseado na correção das hérnias perineais, e pode ser realizado por acesso perineal, abdominal ou abdominoperineal. O perineal (local ou sacrococcígeo), sem a morbidade da laparotomia, é viável para os pacientes não submetidos à cirurgia oncológica ou radioterapia, permitindo a reconstrução com tecidos locais, como no avanço miocutâneo, associado ou não ao uso de telas, com baixa incidência de complicações e bons resultados. O objetivo deste artigo é apresentar o caso de uma paciente submetida à sacrococcigectomia por coccigodinia refratária ao tratamento clínico, que evoluiu com hérnia sacrococcígea sintomática tratada com a correção do defeito com tela de politetrafluoretileno e síntese das camadas suprajacentes, associada ao avanço miocutâneo bilateral tipo V-Y, com o glúteo maior. Serão enfatizados detalhes técnicos e o grau de dificuldade da reconstrução. Após seguimento de três anos, a paciente se encontra em acompanhamento ambulatorial sem recidiva. (AU)


Subject(s)
Humans , Female , Aged , Sacrococcygeal Region/surgery , Hernia/therapy , Perineum/surgery , Surgical Mesh
9.
Acta cir. bras ; 27(7): 454-459, jul. 2012. ilus, graf, tab
Article in English | LILACS | ID: lil-640092

ABSTRACT

PURPOSE: To study the intraperitoneal use of polyester with collagen and polytetrafluoroethylene meshes in the correction of total ventral wall defects in rats. METHODS: Thirty two rats were evaluated and divided randomly into four groups and underwent laparotomy and preparation of total defects of the abdominal wall. Next, the correction of the defect with the intraperitoneal placement of the chosen mesh was performed. The rats were submitted to euthanasia at 30 and 90 days after surgery. Were analyzed the macroscopic adhesions and microscopic aspects, and applied stress rupture test RESULTS: All animals showed intraperitoneal adhesions in varying degrees, with no statistical significance difference. There was no difference also between groups in the evaluation of stress rupture tests. On the microscopic aspect, the A30 group had less inflammatory reaction and less formation of granulomas and foreign body reaction that the B30 group, with significant difference. CONCLUSIONS: There was no difference in intraperitoneal adhesion and tensile rupture strength among groups. Group B30 presented granulomatous inflammatory reaction at the site of mesh attachment to the wall significantly higher than the A30.


OBJETIVO: Estudar comparativamente o uso intraperitoneal das telas de poliéster com colágeno e politetrafluoretileno na correção de defeitos totais da parede ventral em ratos. MÉTODOS: Foram avaliados 32 ratos distribuídos em quatro grupos aleatórios e submetidos à laparotomia e confecção de defeitos totais da parede abdominal. Em seguida, foi realizada a correção do defeito com a colocação intraperitoneal das telas. A eutanásia ocorreu aos 30 e 90 dias do pós-operatório. Foram analisadas as aderências macroscópicas, aspectos microscópicos e aplicado teste de tensão de ruptura. RESULTADOS: Todos os animais apresentaram aderências abdominais intraperitoneais em vários graus, sem significância estatística. Não houve diferença entre os grupos na avaliação dos testes de tensão de ruptura. Na análise microscópica o grupo A30 teve menor reação inflamatória e formação de granulomas, e menor reação do tipo corpo estranho quando comparado ao grupo B30, com resultados significativos. CONCLUSÕES: Não houve diferença significativa entre os grupos tanto em relação à formação de aderências intraperitoneais quanto à tensão de ruptura. O grupo B30 apresentou reação inflamatória e formação granulomatosa no local de fixação na parede significativamente maior que o grupo A30.


Subject(s)
Animals , Male , Rats , Abdominal Wall/surgery , Collagen/adverse effects , Polytetrafluoroethylene/adverse effects , Surgical Mesh/adverse effects , Wound Healing/physiology , Abdominal Wall/pathology , Hernia, Ventral/surgery , Herniorrhaphy/methods , Materials Testing , Random Allocation , Rats, Wistar , Tensile Strength , Time Factors , Tissue Adhesions/etiology , Tissue Adhesions/pathology
10.
J. Health Sci. Inst ; 29(4)oct.-dec. 2011. ilus
Article in Portuguese | LILACS | ID: lil-641412

ABSTRACT

Objetivo - Avaliar a influência do uso de membrana alternativa de PTFE (politetrafluoretileno) na regeneração tecidual guiada em defeitos periodontais de ratos. Métodos - Foram utilizados 20 ratos, machos, divididos em grupos controle e teste. Foi criado um defeito ósseo em mandíbula no periodonto de suporte do incisivo inferior direito. O grupo teste recebeu a membrana de PTFE; o grupo controle foi preenchido por coágulo. Os resultados foram avaliados por microscopia de luz e microscopia eletrônica de varredura, aos 7 e 21 dias. Resultados - Ocorreu neoformação óssea parcial em todos os casos analisados; no grupo teste ocorreu separação entre a membrana e os tecidos circundantes, e houve diferença no sentido tanto das fibras colágenas quanto da deposição óssea. Conclusão - A membrana experimental de teflon foi eficaz como barreira física e separou o ambiente do defeito da mucosa e submucosa; no entanto, alterou a biologia do reparo, mudando o padrão de deposição de matriz óssea em relação à fisiologia normal.


Objective - To assess the influence of an experimental PTFE membrane in guided tissue regeneration in rats. Methods - Twenty male rats were divided in control and test groups. A surgical defect was created in the mandible, at the periodontium of the right lower incisor. The test group received the PTFE membrane and in the control group the defect was filled with blood clot. The results were assessed by light microscopy and scanning electron microscopy at 7 and 21 days. Results - Partial bone neoformation was shown in all cases; in the test group it did not joined the surrounding tissues. There was a microscopic difference between the groups regarding the direction of the collagen fibersand osseous neoformation. Conclusion - The experimental PTFE membrane worked efficiently as a physical barrier, separating the defect environment from the mucosa and submucosa; however it changed the repair biology and the pattern of bone matrix deposition in relation to the normal physiology.

11.
Rev. bras. cir. plást ; 26(3): 461-465, July-Sept. 2011. ilus, tab
Article in English | LILACS | ID: lil-608205

ABSTRACT

BACKGROUND: Many autogenous and exogenous materials have been frequently used for the production of grafts and implants in rhinoplasties. The ideal graft or implant should be biocompatible, biointegrated, non-absorbable, and easily moldable and should not cause an inflammatory response. Gore-tex, an expandable form of polytetrafluoroethylene (PTFE) has been used since the 1970s for vascular graft production. Although Gore-tex is extremely versatile and has extensive uses and low complication rates, the demonstration of Gore-tex use in aesthetic surgery is very limited in medical literature. METHODS: We performed a retrospective study of 7 patients who received Gore-tex implants in order to fill the nasal dorsum from January 2005 to December 2007. All patients were assessed for aesthetic and functional factors and for the presence or absence of complications. RESULTS: All patients had good postoperative evolution, with great satisfaction in terms of aesthetic and functional aspects and no complications. CONCLUSIONS: Gore-tex is a satisfactory synthetic material as it is inexpensive, easily moldable, has good biocompatibility, and has shown no incidence of extrusion or infection in implants used for nasal dorsum filling in previously reported cases.


INTRODUÇÃO: Muitos materiais autógenos e exógenos vêm sendo utilizados com frequência para confecção de enxertos e implantes nas rinoplastias. O enxerto ou implante ideal deve ser biocompatível, biointegrável, não-absorvível, facilmente moldável e não deve causar resposta inflamatória. O Gore-tex, uma forma expansível do politetrafluoretileno (PTFE), é usado desde a década de 1970 na confecção de próteses vasculares. Apesar de seu uso ser extremamente versátil e extenso, oferecendo baixas taxas de complicação, a demonstração na literatura médica de seus resultados, quando usado na cirurgia estética, é muito restrita. MÉTODO: Realizado estudo retrospectivo sobre a evolução de 7 pacientes submetidos a implantes de Gore-tex visando ao preenchimento do dorso nasal, no período de janeiro de 2005 a dezembro de 2007. Todos os pacientes foram avaliados quanto a fatores estéticos e funcionais, e quanto à presença ou não de complicações. RESULTADOS: Todos os pacientes tiveram boa evolução pós-operatória, com grande satisfação do ponto de vista estético e funcional, e sem complicações. CONCLUSÕES: O Gore-tex mostrou-se um material sintético satisfatório, de baixo custo, facilmente moldável, com boa biocompatibilidade e com incidência nula de extrusão ou infecção para implantes de preenchimento de dorso nasal nos casos apresentados.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , History, 21st Century , Patients , Polytetrafluoroethylene , Prostheses and Implants , Rhinoplasty , Surgery, Plastic , Retrospective Studies , Transplants , Esthetics , Polytetrafluoroethylene/standards , Polytetrafluoroethylene/therapeutic use , Prostheses and Implants/standards , Rhinoplasty/methods , Surgery, Plastic/methods , Nose , Nose/surgery , Nose/transplantation , Transplants/surgery
12.
Acta cir. bras ; 26(4): 247-252, July-Aug. 2011. ilus
Article in English | LILACS | ID: lil-594342

ABSTRACT

PURPOSE: Analyze the morphological and structural outcomes of a patch of expanded polytetrafluoroethylene in the treatment of an iatrogenic injury of the common bile duct. METHODS: In Group 1 (Sham), 7 dogs underwent 3 laparotomies with intervals of 30 days between them. In Group 2, 10 dogs underwent transient common bile duct obstruction. After 30 days, this biliary occlusion was undone and a patch of expanded polytetrafluoroethylene replaced a fragment removed from the duct's wall. Thirty days after this last surgery, cholangiographic assessment of prosthesis patency and macro and microscopic evaluation of the biliary tract were performed. Daily clinical inspection completed the study outcomes. The Wilcoxon non-parametric test was used for statistical analysis. RESULTS: In all dogs enlargement of the biliary tree diameter was observed 30 and 60 days after the first surgical procedure. Partial adhesion of the patch to the common bile duct as a free luminal foreign body was found in 6 dogs. The prosthesis was completely integrated to surrounding tissue in the remaining four. CONCLUSION: Although a feasible option for the treatment of biliary duct iatrogenic lesions, the expanded polytetrafluoroethylene prosthesis must be used with caution considering the potential risks for complications.


OBJETIVO: Analisar, evolutivamente, a morfologia e a estrutura de um fragmento de politetrafluoretileno expandido utilizado no tratamento de uma lesão iatrogênica do ducto biliar comum. MÉTODOS: No grupo 1 (Simulação), sete cães foram submetidos a três laparotomias com intervalos de 30 dias entre elas. No grupo 2, em dez cães realizou-se uma obstrução tansitória do ducto biliar comum. Após 30 dias, a oclusão biliar foi desfeita e um fragmento da parede ductal foi substituído por um retalho de politetrafluoretileno expandido. Trinta dias após esta última operação, foram efetuadas uma avaliação colangiográfica da perviedade da prótese e uma análise macro e microscópica do trato biliar. Inspeções clínicas diárias completaram o estudo evolutivo. O teste não paramétrico de Wilcoxon foi utilizado para análises estatísticas. RESULTADOS: Decorridos 30 e 60 dias do primeiro procedimento cirúrgico, observou-se, em todos os cães, aumento do diâmetro da árvore biliar. Em seis cães verificou-se a presença do fragmento da prótese parcialmente aderido à parede do ducto biliar comum e também solta no lúmen da via biliar. A prótese estava completamente integrada aos tecidos circunvizinho nos demais quarto animais. CONCLUSÃO: A prótese de politetrafluoretileno expandido apresenta-se como uma opção factível para o tratamento das lesões iatrogênicas do ducto biliar, entretanto, deve ser utilizada com cautela, considerando o risco potencial de complicações.


Subject(s)
Animals , Dogs , Common Bile Duct/injuries , Prostheses and Implants , Polytetrafluoroethylene/therapeutic use , Biliary Tract Surgical Procedures/methods , Cholangiography , Materials Testing , Organ Size , Postoperative Period , Prostheses and Implants/adverse effects , Time Factors , Treatment Outcome
13.
Full dent. sci ; 1(3): 224-230, abr.-jun. 2010. ilus
Article in Portuguese | LILACS, BBO | ID: lil-642943

ABSTRACT

O reparo de defeitos ósseos é um desafio para diversas áreas, pois a invasão de células fibroblásticas no defeito, resulta em tecido conjuntivo cicatricial. Assim, os princípios de Regeneração Tecidual Guiada (RTG) estão bem estabelecidos para tratamento de defeitos ósseos. Essa técnica consiste na utilização de biomembranas que agem como barreiras e evitam a invasão dos fibroblastos e permite o povoamento com células osteoprogenitoras. O presente trabalho propôs-se avaliar o crescimento e potencial regenerativo em defeitos ósseos através de avaliações macroscópicas e radiográficas. Para tanto, 27 coelhos foram divididos em 3 grupos experimentais de acordo com o tratamento: Controle (A), Látex (B) e PTFE (C). Então, subdivididos em 3 grupos para análise de neoformação periódica: 15 (I); 30 (II) e 60 dias (III). As cobaias foram submetidas à cirurgia para confecção de defeitos ósseos críticos em calvária e tratamento específico de cada grupo. Após os períodos os animais foram sacrificados e obtidas as peças anatômicas para as radiografias pelo método Digora e fotografias digitais. As análises macroscópicas permitiram observar crescimento ósseo e áreas radiopacas sugestivas de tecido ósseo. No período de 15 dias a densidade óssea nos grupos experimentais no defeito foi semelhante. Contudo, aos 60 dias, verificou-se formação óssea homogênea para Látex e vários níveis de radiopacidade para PTFE e controle. Dentro das limitações, conclui-se que biomembranas são bem indicadas em processos cirúrgicos para regeneração óssea, visto que as barreiras impedem ou dificultam a migração de células incompatíveis com o tecido a ser neoformado e promove a osteogênese.


The repair of bone defects is challenge for many areas, since the invasion of fibroblast cells in the defect, resulting in scar tissue. Thus, the principles of Guided Tissue Regeneration (GTR) are well established for treatment of bone defects. This technique is the use of bio-membranes that act as barriers and prevent the invasion of fibroblasts and allows the placement of osteoprogenitor cells. The proposition of this study is evaluate the mechanical growth and regenerative potential in bone defects by macroscopic and radiographic analyses. Twenty-seven rabbits were divided into 3 groups according to treatment: control (A), Latex (B) and PTFE (C). Then divided into 3 groups for analysis of periodic neoformation: 15 (I), 30 (II) and 60 days (III). The animals were subjected to surgical preparation of bone defects in critical calvaria and specific treatment of each group. After the period, they were sacrificed and collected the body parts for X-rays by the Digora method and digital photographs. Macroscopic analysis allowed observed bone growth and areas suggestive of bone tissue. During 15 days of bone density in the experimental groups in the defect was similar. However, after 60 days, there was bone formation for homogeneous in group of Latex and various levels of radiopacity to PTFE and control. Within the experimental conditions, the biomembranes are well indicated in surgical procedures for bone regeneration, since the barriers preventing or hindering cell migration incompatible with the tissue to be newly formed and promotes osteogenesis.


Subject(s)
Animals , Rabbits , Bone Regeneration , Guided Tissue Regeneration , Latex/analysis , Membranes/transplantation , Osteogenesis/immunology , Polytetrafluoroethylene , Diagnostic Imaging , Materials Testing
14.
ImplantNews ; 7(2): 175-178, 2010. ilus
Article in Portuguese | LILACS, BBO | ID: lil-556179

ABSTRACT

A técnica de Regeneração Óssea Guiada (ROG) tem sido utilizada para favorecer a cicatrização do alvéolo e para modificar significativamente o processo de reabsorção do rebordo alveolar. A membrana de Politetrafluoretileno denso (d-PTFE) apresenta a vantagem de impedir a penetração bacteriana, mesmo quando exposta, apresentando ótimos resultados clínicos, principalmente após a exodontia. Este trabalho apresenta casos de manutenção de rebordos alveolares que foram avaliados clinicamente no momento da instalação de implantes osseointegráveis. Cem rebordos alveolares, em regiões de molares e pré-molares inferiores, que foram submetidos à exodontia e imediata instalação de membranas de d-PTFE, foram avaliados. As membranas foram adaptadas entre as paredes ósseas preservadas e o tecido gengival vestibular e lingual, 3 mm a 5 mm apicalmente as margens ósseas dos alvéolos. Os alvéolos que apresentaram perda da parede óssea vestibular foram preenchidos com osso liofilizado para evitar o colapso da membrana. As membranas foram mantidas nos alvéolos por um período de 28 dias. Durante o período de manutenção da membrana sobre o alvéolo, não foi observada inflamação dos tecidos adjacentes. Previamente à instalação dos implantes, as áreas tratadas foram avaliadas clinicamente. Todos os sítios apresentaram gengiva queratinizada, além de formação óssea suficiente para instalação de implantes osseointegráveis.


The biologic principle of guided bone regeneration has been successfully used to enhance bone formation. The dense polytetrafluoroethylene membrane (d-PTFE) resists the incorporation of bacteria into its structure and can be left exposed in the mouth with a low risk of infection, showing excellent clinical results after tooth extraction. This study presents cases of alveolar ridge maintenance evaluated prior to dental implant placement. One hundred cases of alveolar ridge maintenance using intentionally exposed d-PTFE membranes, immediately after tooth extraction, in single molars or bicuspids lower teeth, were evaluated. All sites received a membrane which was trimmed and placed over the extraction socket to cover at least 3 mm to 5 mm of the surrounding bone. In cases where the buccal bone wall was lost, lyophilized bone was used to prevent membrane collapse. Membranes were kept in place for 28 days. No signs of infection were observed. Prior to implant placement, treated areas were clinically evaluated. All sites showed satisfactory bone formation and normal keratinized gingival tissues with suitable conditions for implant placement.


Subject(s)
Humans , Bone Regeneration , Polytetrafluoroethylene , Tooth Socket
15.
RSBO (Impr.) ; 6(3): 256-263, set. 2009. ilus
Article in Portuguese | LILACS | ID: lil-524076

ABSTRACT

Introdução: Atualmente o Teflon possui várias aplicações biológicas e é utilizado tanto em medicina como em odontologia. Na odontologia, é empregado principalmente como barreira, nas técnicas de regeneração tecidual guiada (RTG) e regeneração óssea guiada (ROG), apresentando diferentes níveis de sucesso. Objetivo: O objetivo do presente estudo foi avaliar histologicamente o uso de uma película de Teflon sobre defeitos ósseos intraorais criados cirurgicamente em ratos. Material e métodos: Foram usados 16 ratos machos (Wistar) adultos, os quais foram divididos em 2 grupos: grupo T (teste) e grupo C (controle). Dois tempos experimentais foram analisados, com 1 e 3 semanas. Os defeitos ósseos foram cirurgicamente criados na mandíbula, unilateralmente, por ação de broca esférica multilaminada (Carbide) de 3 mm de diâmetro anteriormente à região mentoniana dos animais. No grupo T, o defeito ósseo foi recoberto com uma película de Teflon (politetrafluoretileno expandido, PTFE-e). No grupo C, o defeito foi preenchido somente com coágulo sanguíneo. Esperou-se o tempo necessário e realizou-se a eutanásia dos animais. Resultados: Em virtude da alta maleabilidade, a película de Teflon acabou por preencher os defeitos experimentais, o que gerou uma reação tecidual local caracterizada pela presença de infiltrado inflamatório crônico e agudo, tanto no grupo T de 1 semana como no grupo T de 3 semanas. No grupo T de 3 semanas observou-se o desenvolvimento de tecido ósseo com mineralização inicial da matriz apenas a partir das bordas do defeito. O desenvolvimento ósseo a partir das bordas também aconteceu no grupo C, com ausência de processos inflamatórios intensos; no entanto a manutenção do volume tecidual foi baixa. Conclusão: No modelo experimental apresentado, concluiu-se que o preenchimento do defeito ósseo pela película de Teflon foi prejudicial ao reparo ósseo local. Para uso dessa película em técnicas regenerativas é necessário melhorar as propriedades física...


Introduction: Today, Teflon is used for many biological applications in medicine and dentistry. In dentistry, it is used especially as a barrier, in the guided tissue regeneration (GTR) and guided bone regeneration (GBR) techniques, presenting different levels of success. Objective: The objective of the present study was to evaluate through histological analysis the use of a Teflon film placed over intra-oral bone defects surgically created in rats. Material and methods: 16 adult male rats (WISTAR) were divided in two groups: group T (test) and C (control). Two experimental monitoring periods were analyzed: one and three weeks. Bone defects were surgically created in the right mandible, with the use of a carbide bur (3 mm diameter), anterior to the mentonian region. In T group, bone defect was covered with a film of Teflon (expanded polytetrafluoroethylene, e-PTFE). In C group, defect was filled only with blood clot. After monitoring periods went through, animals were euthanized. Results: Due to the high malleability Teflon film filled the experimental defects, which caused a local tissue response characterized by the presence of a chronicle and acute inflammatory infiltrate, either at 1 or 3 weeks T groups. In 3-week T group, it was possible to observe the development of bone tissue with initial matrix mineralization only from the edges of the defect. Bone development from the edges also happened in C group, with absence of intense inflammatory processes. However, maintenance of tissue volume was poor. Conclusion: In the presented experimental model it was possible to conclude that filling bone defect with Teflon film was prejudicial to local bone repair. To use Teflon film for regenerative techniques it is necessary to improve physical properties, diminishing its malleability.

16.
Arq. bras. oftalmol ; 72(1): 79-83, jan.-fev. 2009. ilus
Article in Portuguese | LILACS | ID: lil-510026

ABSTRACT

OBJETIVO: Relatar a experiência com o uso do fio de politetrafluoretileno nas cirurgias de suspensão ao músculo frontal para correção de blefaroptose. MÉTODOS: Foram estudados todos os casos de blefaroptose grave submetidos à cirurgia pela técnica de suspensão ao músculo frontal como fio de politetrafluoretileno, no período de fevereiro de 2003 a abril de 2007. Foram realizadas 36 cirurgias em 23 pacientes, a média de seguimento foi de 15,8 meses (variando de 3 a 36 meses). A técnica cirúrgica utilizada foi a descrita por Fox. RESULTADOS: Entre as causas de blefaroptose foram encontradas: congênita em 20 (86,95 por cento) pacientes, blefarofimose em 2 (8,69 por cento) pacientes e traumática em 1 (4,35 por cento) paciente. Na primeira semana de pós-operatório, 6 (26,08 por cento) pacientes referiram assimetria palpebral, 4 (17,39 por cento) notaram edema local, 3 (13,04 por cento) pacientes apresentaram granuloma no local do fio e 1 (4,35 por cento) paciente apresentou celulite facial na região frontal unilateral. Após 3 meses de seguimento, 3 (13,04 por cento) pacientes referiram assimetria palpebral, e em 1 (4,35 por cento) paciente persistia o granuloma. CONCLUSÃO: O politetrafluoretileno - Modelo CV3, 6.0 (Gore-Tex®; W.L. Gore & Associates Inc, Flagstaff, AZ, EUA) é um material adequado com bons resultados funcionais (86,9 por cento), baixos índices de complicação (4,35 por cento) e insatisfação (13,4 por cento), podendo ser uma alternativa em relação à fáscia lata, na cirurgia de suspensão ao frontal para tratamento de ptose palpebral grave.


PURPOSE: To evaluate the functional results and complications of the use of expanded polytetrafluoroethylene in frontalis suspension surgery for the treatment of blepharoptosis. METHODS: Frontalis suspension procedure with polytetrafluoroethylene was performed between 2003 and 2007 on 23 patients (36 eyes) with blepharoptosis. An average follow-up time was 15.8 months (range, 3 to 36). Surgical technique used was described by Fox. RESULTS: The causes of blepharoptosis found were: congenital in 20 patients (86.95 percent), blepharophimosis in 2 (8.69 percent) and traumatic in 1 (4.35 percent). At the first week of postoperatory 6 (26.08 percent) patients related palpebral asymmetry, 4 (17.39 percent) noticed local edema, 3 (13.04 percent) presented granulomas and 1 (4.35 percent) presented facial cellulitis on the ipsilateral frontal region. After 3 months of follow-up 3 (13.04 percent) patients related palpebral asymmetry and 1 (4.35 percent) persisted the granuloma. CONCLUSION: Polytetrafluoroethylene - Model CV3, 6.0 (Gore-tex®, W.L. Gore & Associates Inc, Flagstaff, AZ, EUA) is an adequate material with good functional results (86.9 percent), relatively few complications (4.35 percent) and insatisfaction (13.4 percent) that could be an alternative for fascia lata in the surgery of frontalis suspension for the treatment of blepharoptosis.


Subject(s)
Adolescent , Adult , Child , Child, Preschool , Female , Humans , Male , Middle Aged , Young Adult , Blepharoptosis/surgery , Eyelids/surgery , Oculomotor Muscles/surgery , Polytetrafluoroethylene/therapeutic use , Blepharoptosis/etiology , Follow-Up Studies , Patient Satisfaction , Treatment Outcome , Young Adult
17.
Rev. odontol. UNESP (Online) ; 38(1): 59-63, jan.-fev. 2009. ilus
Article in Portuguese | LILACS, BBO | ID: lil-621784

ABSTRACT

O objetivo deste relato de caso clínico é apresentar a utilização da fita de politetrafluoretileno (PTFE) para facilitar a técnica de reprodução anatômica durante a restauração de incisivos centrais superiores. Paciente do sexo feminino, 10 anos de idade, apresentou-se na Clínica de Dentística Operatória e Estética da Universidade Peruana Cayetano Heredia - UPCH, para a realização de restaurações nos dentes 21 e 11. Os dentes foram preparados, de acordo com as técnicas convencionais. Em seguida, os dentes adjacentes foram secos e recobertos com um pedaço de fita de PTFE. Os dentes foram, então, restaurados, utilizando-se uma resina composta de nanopartículas, por meio das técnicas da matriz de silicone e da técnica incremental. No final da restauração, a fita de PTFE foi removida e procederam-se o acabamento e o polimento das restaurações. Após o término da restauração, uma aparência estética e natural do dente fraturado foi conseguida, satisfazendo as expectativas funcionais e estéticas do paciente.


The aim of this case report is to present the use of PTFE tape to make easier the copy of anatomic details, during the restoration of maxillary central incisors. A 10-year-old girl attended the Dental Clinic of the Universidad Peruana Cayetano Heredia - UPCH with fracture in the teeth 21 and 11. The teeth were prepared, in according to conventional techniques. Next, the adjacent teeth were dry and covered with a piece of tape of PTFE. The teeth were restored using a composite resin of nanoparticles, through the techniques of the silicon matrix and composite stratification. When the restoration was finished, the tape of PTFE was removed and the finishing and polishing of the restorations were made. After the restoration, an aesthetic and natural appearance of toothfracture was achieved, satisfying the expectations and functions of the patient.


Subject(s)
Humans , Female , Child , Polytetrafluoroethylene , Tooth Fractures , Composite Resins , Dental Cements , Esthetics, Dental , Incisor
18.
Acta cir. bras ; 23(2): 184-191, Mar.-Apr. 2008. ilus
Article in English | LILACS | ID: lil-478756

ABSTRACT

PURPOSE: To evaluate the Load of Rupture of implants of membranes of microbial cellulose (Zoogloea sp.) and extended polytetrafuoroethylene in sharp defects of abdominal wall of rats. METHODS: Sixty Wistar male rats, with a mean weight of 437,7g ± 40,9, anesthetized by a mixture of ketamine (5mg/100g) and xylazine (2mg/100g), were submitted to a rectangular (2x3cm) excision of the abdominal wall, including fascia, muscle and peritoneum, and treated with membranes of microbial cellulose (MC) (MC Group- 30 animals) or extended polytetrafluoroethylene (ePTFE) (ePTFE Group- 30 animals). Each group was subdivided in 14th POD, 28th POD and 60th POD Subgroups. Under anesthesia, animals were submitted to euthanasia at 14th POD, 28th POD and 60th POD for evaluation of Load of Rupture. RESULTS: Load of Rupture levels were significantly elevated (p<0, 05) among 14th, 28th and 60th postoperative days from each Group. When compared between groups, values of Load of Rupture were significantly larger (p<0, 05) in ePTFE Group than in MC Group. CONCLUSION: Resistance to strength at implant/host interface was more pronounced in PTFEe Group than in MC Group.


OBJETIVO: Avaliar a Carga de Ruptura de implantes de membranas de celulose microbiana (Zoogloea sp.) e de politetrafluoretileno expandido em defeitos agudos produzidos na parede abdominal de ratos. MÉTODOS: Sessenta ratos machos Wistar, com média de peso de 437,7g ± 40,9, anestesiados com uma mistura de cetamina (5mg/100g) e xilazina (2mg/100g), foram submetidos à excisão retangular (2x3cm) na parede ventral do abdômen, incluindo fáscia, músculo e peritônio. Subseqüentemente, foram tratados com implante de membranas de celulose microbiana (CM) (Grupo CM - 30 animais) ou de politetrafluoretileno expandido (PTFEe) (Grupo PTFEe - 30 animais). Cada grupo foi ainda subdividido nos Subgrupos 14º DPO, 28º DPO e 60º DPO. Os animais foram submetidos à eutanásia com doses letais de tiopental no 14º DPO, 28º DPO e 60º DPO, para avaliação da Carga de Ruptura na área do implante. RESULTADOS: Os níveis da Carga de Ruptura foram significativamente elevados (p<0,05) entre os Subgrupos 14º DPO, 28º DPO e 60º DPO de cada grupo estudado. Quando comparados entre Grupos, os valores da Carga de Ruptura foram significativamente maiores (p<0,05) no Grupo PTFEe do que no Grupo CM. CONCLUSÃO: A interface implante/hospedeiro apresentou maior resistência a tração no Grupo PTFEe do que no Grupo CM.


Subject(s)
Animals , Male , Rats , Abdominal Wall/surgery , Cellulose/therapeutic use , Membranes, Artificial , Polytetrafluoroethylene/therapeutic use , Tensile Strength/physiology , Zoogloea , Abdominal Injuries/surgery , Biocompatible Materials , Biomechanical Phenomena , Materials Testing , Rats, Wistar , Time Factors
19.
Acta cir. bras ; 23(1): 78-83, Jan.-Feb. 2008. ilus, tab
Article in English | LILACS | ID: lil-474144

ABSTRACT

PURPOSE: Biomaterials may be used as treatment of great abdominal wall defects to avoid tension during repair. In the present research we intended to investigate incorporation type by host tissue of membranes of microbial cellulose (MC), produced by the bacteria Zoogloea sp., and of polytetrafluoroethylene (ePTFE) in abdominal wall defects of rats. METHODS: Sixty male rats Wistar, anesthetized by ketamine (5mg/100g) and xylazine (2mg/100g), were submitted to a rectangular excision (2x3cm) of the abdominal wall, including fascia, muscles and peritoneum and further treated with implants of microbial cellulose (MC Group - 30 animals) or expanded polytetrafluoroethylene ( ePTFE Group- 30 animals). Each group was subdivided in 14th DPO, 28th DPO and 60th DPO Subgroups. RESULTS: Incorporation of biomaterials was observed by wrapping and infiltration by host tissue. It has been found that wrapping associated to infiltration of host connective tissue in implants of ePTFE were present in 100 percent of the observed samples, and this may be responsible for increase resistance to traction. Inversely, wrapping without host tissue infiltration was seen in 100 percent of examined specimens of MC implants. CONCLUSION: Wrapping and host tissue infiltration is seen only in ePTFE implants.


OBJETIVO: Biomateriais podem ser usados como tratamento de grandes defeitos da parede abdominal para evitar tensão durante reparo. Na presente pesquisa pretendeu-se investigar o tipo de incorporação pelo tecido do hospedeiro de membranas de celulose microbiana (CM), produzidas pela bactérias Zoogloea sp., e de politetrafluoretileno (PTFEe) em defeitos da parede abdominal de ratos. MÉTODOS: Sessenta ratos machos Wistar, anestesiados através de cetamina (5mg/100g) e xilazina (2mg/100g), foram submetidos a uma excisão retangular (2x3cm) da parede abdominal, incluindo fascia, músculos e peritoneum e posteriormente tratadas com implantes de celulose microbiana (Groupo CM - 30 animais) ou politetrafluoretileno (Grupo PTFEe - 30 animais). Cada grupo foi subdividido em Subgrupos14º DPO, 28º DPO e 60º DPO. RESULTADOS: Incorporação do biomaterial foi observada através de envoltório e infiltração pelo tecido do receptor. Foi encontrado que o envoltório associado à infiltração de tecido conjuntivo do hospedeiro em implantes de ePTFE estava presente em 100 por cento das amostras observadas, podendo ser responsável por aumento da resistência à tração. Inversamente, envoltório sem infiltração de tecido do hospedeiro foi visto em 100 por cento dos espécimes examinados nos implantes de CM. CONCLUSÕES: Pode-se ser concluído que o envoltório associado à infiltração de tecido do hospedeiro só é vista nos implantes de PTFEe.


Subject(s)
Animals , Male , Rats , Abdominal Wall/surgery , Biocompatible Materials , Cellulose , Implants, Experimental , Wound Healing/physiology , Bacteria/metabolism , Materials Testing , Membranes, Artificial , Rats, Wistar , Surgical Flaps , Tissue Adhesions
20.
J. vasc. bras ; 6(2): 130-141, jun. 2007. ilus, graf
Article in Portuguese | LILACS | ID: lil-462272

ABSTRACT

CONTEXTO: O desenvolvimento de prótese vascular tem sido vital para os avanços e realizações da cirurgia vascular reconstrutora durante as últimas 5 décadas. OBJETIVOS: Desenvolver um novo modelo de prótese vascular microperfurada, confeccionada em tecido recoberto com um composto derivado do látex natural da seringueira (Hevea brasiliensis) e avaliar sua perviedade, trombogenicidade, biocompatibilidade e o processo de cicatrização, além de algumas propriedades mecânicas (adaptabilidade, elasticidade, impermeabilidade e possibilidade de sutura), utilizando como controle a prótese de politetrafluoretileno expandido no mesmo animal. MÉTODOS: Quinze cães foram separados em três grupos de cinco animais. Implantou-se a prótese de tecido e látex microperfurada e, no membro pélvico contralateral, a prótese de politetrafluoretileno expandido em todos os cães. O seguimento pós-operatório foi de 4, 8 e 12 semanas. A apreciação dos resultados foi feita segundo as avaliações clínicas dos pulsos, complicações (coleção líquida, deiscência, granuloma e infecção), arteriografias, análise macroscópica e elétron-micrografias de varredura. RESULTADOS: Os testes estatísticos aplicados não evidenciaram diferenças significativas (p > 0,05) em relação às complicações pós-operatórias e perviedade dos enxertos. Ambas as próteses integraram-se adequadamente aos tecidos circunvizinhos, com um tecido de incorporação formado por fibras colágenas. Constatou-se a presença de neoíntima recoberta por endotélio em toda a extensão da superfície luminal da prótese de tecido e látex microperfurada. Ao contrário, na prótese de politetrafluoretileno expandido, o desenvolvimento endotelial sobre a superfície neointimal limitou-se às regiões próximas às anastomoses. CONCLUSÕES: A prótese de tecido e látex microperfurada demonstrou qualidades estruturais (adaptabilidade, elasticidade, impermeabilidade e possibilidade de sutura) satisfatórias como substituto vascular. Estimulou...


BACKGROUND: The development of vascular grafts has been crucial for advances and achievements in reconstructive vascular surgery over the past 5 decades. OBJECTIVES: To develop a new model of microperforated vascular graft using fabric covered with a natural latex-derived polymer taken from Hevea brasiliensis and assess its patency, thrombogenicity, biocompatibility and healing process, besides some mechanical properties (adaptability, elasticity, impermeability and possibility of suture), using expanded polytetrafluoroethylene graft as control. METHODS: Fifteen dogs were divided into three groups of five animals. The microperforated latex graft was implanted in all dogs and the expanded polytetrafluoroethylene graft was implanted in the contralateral pelvic limb. Postoperative follow-up was 4, 8 and 12 weeks. Analysis of results was performed according to clinical evaluation of pulses, complications (fluid collection, dehiscence, granuloma and infection), arteriography, macroscopic analysis and scanning electron micrography. RESULTS: Statistical tests revealed no significant differences (p > 0.05) concerning post-operative complications and graft patency. Both grafts were properly integrated to surrounding tissues, with connective tissue formed by collagen fibers. A neointimal layer covering all extension of the luminal surface was observed in the microperforated latex graft. Conversely, the endothelial development over the neointimal surface was limited to regions adjacent to the anastomoses in the expanded polytetrafluoroethylene graft. CONCLUSIONS: The microperforated latex graft showed satisfactory structural qualities (adaptability, elasticity, impermeability and possibility of suture) as a vascular substitute. It stimulated endothelial growth beyond contact regions with the artery in anastomoses and was biocompatible in the dog's arterial system, presenting adequate tissue integration.


Subject(s)
Animals , Dogs , Femoral Artery/physiology , Endothelium/surgery , Polytetrafluoroethylene/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL